Aim Research the movement of recoil mechanism under the control of micro computer. Methods According to the mathematical model of controlled recoil system
the curve of controlled leak area and recoil mechanism movement were presented. Results The result of emulated Pressure time Curve is very close to the experiment result. Conclusion The mathematical model and emulation results show reference value of the actual system.