In order to find the reason of the fuze accessories failure and the fuze explosion
the severe environment with high acceleration and high pressure of powder in the bore was analyzed
a multi-dot
multi-axis and multi-parameter composite measurement method was proposed.A corresponded multichannel stored measuring system was designed and was used to test the different-direction stir signals produced by the fuze in the bore.The research indicates that the maximum axial load of the fuze suffering at the muzzle is 2 times higher than that in the bore
and simultaneously the peak radial load is 1.5 times higher.These data have exceeded the design standard of fuse