Explosives coating was conducted by supercritical fluid anti-solvent (SAS)process. With viton F_{2602}
absolute ethylalcohol and CO
2
acts as coating substance
cosolvent and anti-solvent
respectively
the coating effect was investigated by changing the temperature
pressure and speed of CO
2
. The state of coating was analyzed by measuring the performances of coated samples and an SEM observation on the surface of coated explosives. In a result
the temperature of the autoclave is the important parameter to affect the coating result. At the same time
pressure and speed of CO
2
have certain infulence. By controlling the operation parameters
a satisfactory quality of coated explosives was achieved.