王黎明, 张超, 赵英亮, et al. 基于平面成像器件的高分辨率工业CT技术研究[J]. 2007, (6).DOI:
基于平面成像器件的高分辨率工业CT技术研究
摘要
在通用的CT成像系统中
由于面阵探测器像元之间无光隔
成像过程相对线阵探测器而言系统散射影响大
动态范围小
成像指标远低于线阵探测器.采用大探测器方法重组像元
用亚像素高分辨率方法重组和补偿数据
弥补了面阵探测器在动态范围的不足
同时充分利用了面阵的高空间分辨率
得到了较好的CT重建结果.
Abstract
In general CT imaging systems
due to no light isolation among the pixels of flat-panel detectors
more dispersion
less dynamic range and lower imaging parameters consist in imaging process compared with linear detectors.Big-size detectors is adopted to recombine the pixels
and recompose and compensate data by sub-pixel high-resolution approach.The method makes up the deficiency of dynamic range of flat panel detectors
and better CT reconstructed results can be obtained due to high space resolution of the flat panel.